论述直流1500V接触轨系统的安全性,包括系统安全、设备安全、人身安全。通过故障模式后果分析法,对1500V接触轨系统的可靠性进行分析。在对国内外相关规范要求分析的基础上,认为不管是直接接触防护还是间接接触防护,对于人身安全防护标准而言,直流1500V接触轨系统与直流750V接触轨系统是一致的。同时,就涉及1500V接触轨设备自身安全的绝缘距离和爬电距离提出技术要求。阐述直流1500V接触轨系统的安全防护策略,并相应采取一系列安全防护措施。
[Key word]
[Abstract]
ThesafetyofDC1500Vconductrailsystemincludessystemsafety?equipmentsafetyandpersonnelsafety.Thereliability ofDC1500Vconductrailsystemwasanalysedbyfailuremodeconsequencesmethod.Basedontheanalysesaccordingtodomestic andoverseascodes?itwasconcludedthattheprotectivestandardsforpersonnelsafetyarethesamebothforDC1500Vconductrail systemandDC750V conductrailsystem?irrespectiveofwhetherthecontactprotectionisdirectorindirect.Thetechnical requirementsoninsulateddistanceandcreepdistancerelatedtoequipmentsafetyofDC1500Vconductrailsystemareputforward. AuthorsalsoexpoundthesafetyprotectivestrategyforDC1500Vconductrailsystemtogetherwithaseriesofprotectiveprovisions.